Passive and active system in the buildings

Wednesday, 17 January 2018

Fire Door

Salam and good morning to everybody..

Today i will share about fire door. The requirements for fire door clearly stated in Uniform Building By Law 1984 (UBBL 1984).





By-Law 141 (2) (b)

An opening in a separating wall which is necessary as a means of escape from fire, if the opening is fitted with a door which has in respect of separating walls FRP (Fire Resistance Period) of not less than that required in this part.


By-Law 162

It stipulates that all opening in compartment and separating walls shall be protected with fire door having a FRP in accordance with the requirements for that wall specified in the Ninth Schedule of UBBL 1984.


By-Law 164 (1)

Stipulates that all fire doors shall be fitted with automatic door closer of the hydraulically spring operated type in the case of swing door and or wire rope and weight type in the case of sliding door.


By-Law 164 (2)

Double door rabbeted meeting stiles shall be provided with coordinating device to ensure that leaf close in proper sequence.



By-Law 173

All exits doors shall be openable from inside without the use of key or any special knowledge or effort.

By-Law 186 (1)

All doors used by the public as exit doors from any part of the place of assembly or leading to open air shall open only in the direction of exit.

By-Law 186 (2)

In a place of assembly all exits doors and doors through which the public pass on the way to the open air shall be without lock, bolts or other fastening while the public are in the building.

Based on MS 1073 Part 3 1996 Doorsets - Testing of Fire Resistant, all fire doors used in buildings shall be tested and passed together with the designated hardware. Door set means complete set inclusive of door leaf, frame, vision panel, in tumescent and ironmongeries [ lock set, automatic door closer, hinges, door selector, flush bolts, weathering strip, etc ]

Application of fire doors

a) Entrance doors to Fire Protected Staircases, passage way and/or ramps

b) Doors leading into individual fire protected residential occupancies

c) Entrance door to individual fire protected commercial occupancies

d) Institutional or assembly building - path of travel to exits

Other special purpose doors

i) Security fire doorset

ii) Armoured attack - resistance fire doorset

iii) Radiation shielding fire doors

iv) Pressure - resistant fire door

Orait, enough for today.. until we meet again.. c u soon..



7 comments:

  1. I have a question. Did UBBL or Bomba Authority's law to mention Vision Panel Fire Door to use at which area in the mix development building? Or it is subjective/optional to Arch/Client/Designer. Thanks.

    ReplyDelete
  2. Can we repaint fire rated door?

    ReplyDelete
  3. What if residents puts rocks that keep the emergency door open and refuses to listen to advice that the emergency door must be shut at all times

    ReplyDelete
  4. what us the building needed to install fire door? what is the minimum size of the building?

    ReplyDelete
  5. What is the width requirement for the gate of the apartment?

    ReplyDelete
  6. Is there any requirement to use fire door for hose reel / compartment ?

    ReplyDelete
  7. We offer comprehensive fire door inspection services to ensure your building's fire safety compliance. Our certified inspectors assess the condition and functionality of fire doors, checking for proper installation, wear and tear, sealing, and overall performance. We focus on identifying potential risks, such as gaps, faulty hardware, or damaged seals, that could compromise the door’s ability to contain fire and smoke. Regular inspections help prevent costly fines and enhance occupant safety. We provide detailed reports with recommendations for repairs or replacements, ensuring your fire doors meet legal standards and provide optimal protection. If you're interested in learning more about accredited fire door inspections, we invite you to visit this page where you'll find a wealth of resources, including articles, guides, and case studies.

    ReplyDelete